Contacto


BLOWER FANS
AC BLOWER 12131
Size:
121 x 121 x 31( 4.76" x 4.76" x1.22")
Construction:
Spriral housing of fiberglass reinforced polycarbonate. Shaded pole motor. Only lead wire. Precise ball bearing or sleeve bearing system.
Operating Temperature:
Sleeve bearing -10ºC to +70ºC
Ball bearing -20ºC to +80ºC
Insulation resistance:
10 meg Ohms min. at 500V DC
(between frame and terminal)
Dielectric strength:
1500 VAC one minute
Weight:
260 grams
121 x 121 x 31( 4.76" x 4.76" x1.22")
Construction:
Spriral housing of fiberglass reinforced polycarbonate. Shaded pole motor. Only lead wire. Precise ball bearing or sleeve bearing system.
Operating Temperature:
Sleeve bearing -10ºC to +70ºC
Ball bearing -20ºC to +80ºC
Insulation resistance:
10 meg Ohms min. at 500V DC
(between frame and terminal)
Dielectric strength:
1500 VAC one minute
Weight:
260 grams
Model No. | Bearing | Rated voltage(VAC) | Frequency (Hz) | Max.Rated current (mA) | Max.input power (W) | Speed (r.p.m.) | Max. Air Flow (CFM) | Max. Air Pressure (mmH2O) | Noise dB(A) |
KLE115AP120BSWH | Sleeve | 115 | 50/60 | 240/210 | 20.0/18.4 | 2574/2940 | 20/22 | 12.08/13.30 | 46/49 |
KLE115AP120BBWH | Ball | 115 | 50/60 | 240/210 | 20.0/18.4 | 2574/2940 | 20/22 | 12.08/13.30 | 46/49 |
KLE230AP120BSWH | Sleeve | 230 | 50/60 | 130/110 | 18/.8/17.0 | 2600/2940 | 20/22 | 9.10/10.00 | 46/48 |
KLE230AP120BBWH | Ball | 230 | 50/60 | 130/110 | 18.8/17.0 | 2600/2940 | 20/22 | 9.10/10.00 | 46/48 |
-
DC BLOWER 12032 - 1
-
DC BLOWER 12032 - 2